Carbon Steel Waste Heat Exchange Flue Gas Cooler CE ROHS CCC ISO9001 UL

Brand Name : HD Boiler

Model Number : Flue Gas Cooler

Certification : CE,ROHS,CCC,ISO9001,UL

Place of Origin : CHINA

MOQ : 1 set

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 500 tons per month

Delivery Time : 50 days

Packaging Details : Seaworthy packing

Structure : Tube Heat Exchanger,Plate Heat Exchanger,Copper tub

Application : drying or cooling usage for various equipments,Heater Parts,HVAC system

Tube material : carbon steel,copper,aluminum,stainless steel

Color : silver or natural color,Copper

Tube type : Smooth tube,heat pipe

Contact Now

Carbon Steel Waste Heat Exchange Flue Gas Cooler for drying or cooling usage

Product Introduction

  1. Working principle of a flue-gases cooler is the same as in the above-described equipment, but the aim in this case is to cool a primary fluid, not to get a thermal profit by heating a secondary fluid.
  2. These equipment are usually installed as the previous step to a flue-gases cleaning, to avoid the gases from reaching the cleaning systems at too high temperatures. This means an alternative to the dilution with air, which would imply an over-sizing of the mentioned systems.

Specifications

Fuel: Flue Gas Dust Treatment: Sonic Blower / Steam Blower
Pressure: Low Pressure Condition: New
Function: Wate Heat Recovery Port: Shanghai

Details

  • Before designing this kind of equipment, it is necessary to know the nature of the gases to be cooled and their dust content.
  • The purpose of all that is to design an equipment free of important fouling which would force to make cleaning works more frequently than wanted.
  • We must have in mind as well the availability to detach the dust from the gaseous stream containing it in all those areas where there is a bend or some enlarging in the pass section, which forces to include in the design some systems for dust collection and removal, to allow the correct heat exchange.

Efficiency

Flue gas condensation may cause the heat recovered to exceed the Lower Heating Value of the input fuel, and thus an efficiency greater than 100%. Since historically most combustion processes have not condensed the fuel, usual efficiency calculations assume the combustion products are not condensed. This assumption is implicit when basing calculations on the Lower Heating Value. A more rigorous approach would be to base efficiency calculations on the Higher Heating Value, which typically results in efficiencies less than 100%.[citation needed]

Should the flue gases be cooled below 25 °C (77 °F), even efficiencies based on the Higher Heating Value may exceed 100%, since typical heating value definitions assume that all heat is released when combustion products are cooled to somewhere between 15.56 °C (60.01 °F) and 25 °C (77 °F).

Conclusion

To sum up, the following items have to be taken into account when designing a flue-gases cooler:

Kind of fluid.
Dust content.
Maintenance and cleaning works.
Connection of the equipment with the rest of the plant.

Depending on the above mentioned factors, different technical solutions may be applied which will go through the adoption of an arrangement:

Vertical/Horizontal.
Modular (with only one or many fans).
One or more steps.

Packing

Carbon Steel Waste Heat Exchange Flue Gas Cooler CE ROHS CCC ISO9001 UL

Company Information

Established in 1985,Zhangjiagang Hua Dong Boiler Co.,Ltd.(trading as HD Boiler),produces power plant; industrial; waste heat; waste incineration; biomass; organic heat carrier and electric steam boilers. Coupled with a comprehensive range of heating surfaces, HD Boiler brings to the market a unique service including boiler design , fabrication, installation, maintenance and replacement of boiler pressure parts.

1. Fabrication area of 200,000 square meters

2. 150 Engineers

3. 600 Coded welders

4. 60 Licensed Inspectors(NDT Level-III instructors)

5. Class-A Licenses for Design and Manufacture Boiler

6. ISO 9001:2008 Quality System

7. ASME Certificate of Power Boilers

8. ASME 'S','U' and NB stamp authorization

Carbon Steel Waste Heat Exchange Flue Gas Cooler CE ROHS CCC ISO9001 UL


Product Tags:

flue gas heat exchanger

      

flue gas heat recovery

      
China Carbon Steel Waste Heat Exchange Flue Gas Cooler CE ROHS CCC ISO9001 UL wholesale

Carbon Steel Waste Heat Exchange Flue Gas Cooler CE ROHS CCC ISO9001 UL Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhangjiagang HuaDong Boiler Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)